Series 20 - Stainless Steel
2 Way Normally Open - Model 21
Click here for specs


Series 20Series 20
*Max Oper Press Diff. Orifice Size CV Factor
AC DC
GROMMET HOUSING CONDUIT HOUSING
1/8 NPT 1/4 NPT 1/8 NPT 1/4 NPT
REPAIR PACK
400(700) 400(700) 1/32 .024
21G7XGV 21G9ZGV 21G7XCV 21G9ZCV
K21GDX
235(500) 235(500) 3/64 .053
21H7XGV 21H9ZGV 21H7XCV 21H9ZCV
K21HDX
150(350) 150(350) 1/16 .095
21K7XGV 21K9ZGV 21K7XCV 21K9ZCV
K21KDX
100(150) 100(150) 3/32 .156
21J7XGV 21J9ZGV 21J7XCV 21J9ZCV
K21JDX
When Ordering Valves or Repair Packs Add Voltage and Frequency to Complete Valve#.
EXAMPLE: Valve (21G7XGV-120/60) REPAIR PACK (K21GDX-AC)
 

Series 20 - Stainless Steel
2 Way Normally Closed - Model 22
Click here for specs


Series 20Series 20
*Max Oper Press Diff. Orifice Size CV Factor
AC DC    
GROMMET HOUSING CONDUIT HOUSING
1/8 NPT 1/4 NPT 1/8 NPT 1/4 NPT
REPAIR PACK
500 500 1/32 .024
22G7DGV 22G9DGV 22G7DCV 22G9DCV
K22GDD
250(500) 250(500) 3/64 .052
22H7DGV 22H9DGV 22H7DCV 22H9DCV
K22HDD
200(400) 200(400) 1/16 .095
22J7DGV 22J9DGV 22J7DCV 22J9DCV
K22JDD
125(300) 125(300) 3/32 .156
22K7DGV 22K9DGV 22K7DCV 22K9DCV
K22KDD
100(200) 100(200) 1/8 .214
22N7DGV 22N9DGV 22N7DCV 22N9DCV
K22NDD
75 50 5/32 .404
22O7DGV 22O9DGV 22O7DCV 22O9DCV
K22ODD
50 25 3/16 .500
22P7DGV 22P9DGV 22P7DCV 22P9DCV
K22PDD
20 5 1/4 .700
22R7DGV 22R9DGV 22R7DCV 22R9DCV
K22RDD
15 - 5/16 1.000
--- 22S9DGV --- 22S9DCV
K22SDD
When Ordering Valves or Repair Packs Add Voltage and Frequency to Complete Valve#.
EXAMPLE: Valve (22G7DGV-120/60) REPAIR PACK (K22GDD-AC)
 

Series 20 - Stainless Steel
2 Way Normally Closed - Low Pressure - High Flow - Model 22
Click here for specs


Series 20Series 20
*Max Oper Press Diff. Orifice Size CV Factor
AC DC
GROMMET HOUSING CONDUIT HOUSING
3/8 NPT Ports 3/8 NPT Ports
REPAIR PACK
0 - 10
Or up to 15" of mercury
3/8 2.0
22T1DGV 22T1DGV
K22TDD
 

Series 20 - Stainless Steel
3 Way Normally Closed Piped Exhaust - Model 23
Click here for specs


Series 20Series 20
*Max Oper Press Diff. Orifice Size CV Factor
AC DC Inlet Exh Inlet Exh
GROMMET HOUSING CONDUIT HOUSING
1/8 NPT 1/4 NPT 1/8 NPT 1/4 NPT
REPAIR PACK
400 400 1/32 1/32 .024 .024
23GG7XGV 23GG9ZGV 23GG7XCV 23GG9ZCV
K23GGX
150(200) 150(200) 3/64 1/16 .052 .095
23HJ7XGV 23HJ9ZGV 23HJ7XCV 23HJ9ZCV
K23HJX
100(135) 100(135) 1/16 1/16 .095 .095
23JJ7XGV 23JJ9ZGV 23JJ7XCV 23JJ9ZCV
K23JJX
100(135) 100(135) 1/16 3/32 .095 .156
23JK7XGV 23JK9ZGV 23JK7XCV 23JK9ZCV
K23JKX
75(100) 75(100) 3/32 3/32 .156 .156
23KK7XGV 23KK9ZGV 23KK7XCV 23KK9ZCV
K23KKX
50(70) 50(70) 1/8 3/32 .214 .156
23NK7XGV 23NK9ZGV 23NK7XCV 23NK9ZCV
K23NKX
20 20 3/16 3/32 .500 .156
23PK7XGV 23PK9ZGV 23PK7XCV 23PK9ZCV
K23PKX
15 - 1/4 3/32 .700 .156
23RK7XGV 23RK9ZGV 23RK7XCV 23RK9ZCV
K23RKX
When Ordering Valves or Repair Packs Add Voltage and Frequency to Complete Valve#.>
EXAMPLE: Valve (23GG7XGV-120/60) REPAIR PACK (K23GGX-AC)
 

Series 20 - Stainless Steel
3 Way Normally Closed Exhaust to Atmosphere - Model 23
Click here for specs


Series 20Series 20
*Max Oper Press Diff. Orifice Size CV Factor
AC DC Inlet Exh Inlet Exh
GROMMET HOUSING CONDUIT HOUSING
1/8 NPT 1/4 NPT 1/8 NPT 1/4 NPT
REPAIR PACK
400 400 1/32 1/32 .024 .024
23GG7DGV 23GG9DGV 23GG7DCV 23GG9DCV
K23GGD
150(200) 150(200) 3/64 1/16 .052 .095
23HJ7DGV 23HJ9DGV 23HJ7DCV 23HJ9DCV
K23HJD
100(135) 100(135) 1/16 1/16 .095 .095
23JJ7DGV 23JJ9DGV 23JJ7DCV 23JJ9DCV
K23JJD
100(135) 100(135) 1/16 3/32 .095 .156
23JK7DGV 23JK9DGV 23JK7DCV 23JK9DCV
K23JKD
75(100) 75(100) 3/32 3/32 .156 .156
23KK7DGV 23KK9DGV 23KK7DCV 23KK9DCV
K23KKD
50(70) 50(70) 1/8 3/32 .214 .156
23NK7DGV 23NK9DGV 23NK7DCV 23NK9DCV
K23NKD
20 20 3/16 3/32 .500 .156
23PK7DGV 23PK9DGV 23PK7DCV 23PK9DCV
K23PKD
15 - 1/4 3/32 .700 .156
23RK7DGV 23RK9DGV 23RK7DCV 23RK9DCV
K23RKD
When Ordering Valves or Repair Packs Add Voltage and Frequency to Complete Valve#.
EXAMPLE: Valve (23GG7DGV-120/60) REPAIR PACK (K23GGD-AC)
 

Series 20 - Stainless Steel
3 Way Normally Open - Model 24
Click here for specs


Series 20Series 20
*Max Oper Press Diff. Orifice Size CV Factor
AC DC Inlet Exh Inlet Exh
GROMMET HOUSING CONDUIT HOUSING
1/8 NPT 1/4 NPT 1/8 NPT 1/4 NPT
REPAIR PACK
400 400 1/32 1/32 .024 .024
24GG7XGV 24GG9ZGV 24GG7XCV 24GG9ZCV
K24GGX
150(225) 150 3/64 1/16 .052 .095
24HJ7XGV 24HJ9ZGV 24HJ7XCV 24HJ9ZCV
K24HJX
100(150) 100 1/16 1/16 .095 .095
24JJ7XGV 24JJ9ZGV 24JJ7XCV 24JJ9ZCV
K24JKX
100(125) 100 1/16 3/32 .095 .156
24JK7XGV 24JK9ZGV 24JK7XCV 24KK9ZCV
K24JKX
100(125) 100 1/16 3/32 .095 .214
24JK7XGV 24JK9ZGV 24JK7XCV 24JK9ZCV
K24JKX
75(90) 75 1/8 3/32 .156 .214
24KN7XGV 24KN9ZGV 24KN7XCV 24KN9ZCV
K24KNX
When Ordering Valves or Repair Packs Add Voltage and Frequency to Complete Valve#.
EXAMPLE: Valve (24GG7XGV-120/60) REPAIR PACK (K24GGDX-AC)
 

Series 20 - Stainless Steel
3 Way Directional Control - Model 25
Click here for specs


Series 20Series 20
*Max Oper Press Diff. Orifice Size CV Factor
AC DC Inlet Exh Inlet Exh
GROMMET HOUSING CONDUIT HOUSING
1/8 NPT 1/4 NPT 1/8 NPT 1/4 NPT
REPAIR PACK
500 500 1/32 1/32 .024 .024
25GG7XGV 25GG9ZGV 25GG7XCV 25GG9ZCV
K25GGX
235(400) 235(300) 3/64 3/64 .052 .052
25HH7XGV 25HH9ZGV 25HH7XCV 25HH9ZCV
K25HHX
200(225) 200(225) 1/16 3/64 .095 .052
25JH7XGV 25JH9ZGV 25JH7XCV 25JH9ZCV
K25JHX
150(225) 150(200) 1/16 1/16 .095 .156
25JJ7XGV 25JJ9ZGV 25JJ7XCV 25JJ9ZCV
K25JJX
100(150) 100(125) 3/32 3/32 .156 .156
25KK7XGV 25KK9ZGV 25KK7XCV 25KK9ZCV
K25KKX
100(125) 100 1/8 3/32 .214 .156
25NK7XGV 25NK9ZGV 25NK7XCV 25NK9ZCV
K25NKX
When Ordering Valves or Repair Packs Add Voltage and Frequency to Complete Valve#.
EXAMPLE: Valve (25GG7XGV-120/60) REPAIR PACK (K25GGX-AC)
 

Series 20 - Stainless Steel
3 Way Multi Purpose - Model 26
Click here for specs


Series 20Series 20
*Max Oper Press Diff. Orifice Size CV Factor
AC DC Inlet Exh Inlet Exh
GROMMET HOUSING CONDUIT HOUSING
1/8 NPT 1/4 NPT 1/8 NPT 1/4 NPT
REPAIR PACK
400 400 1/32 1/32 .024 .024
26GG7XGV 26GG9ZGV 26GG7XCV 26GG9ZCV
K26GGX
150 150 3/64 3/64 .052 .052
26HH7XGV 26HH9ZGV 26HH7XCV 26HH9ZCV
K26HHX
100 100 1/16 1/16 .095 .095
26JJ7XGV 26JJ9ZGV 26JJ7XCV 26JJ9ZCV
K26JJX
75 75 3/32 3/32 .156 .156
26KK7XGV 26KK9ZGV 26KK7XCV 26KK9ZCV
K26KKX